Customer Application Brief · Semiconductor Metrology · PVX-4110 ---

A publicly traded supplier of advanced metrology solutions for semiconductor manufacturing runs the BNC PVX-4110 10 kV pulse generator in its research and development laboratory. Metrology R&D consumes pulsed high voltage differently than production equipment does: requirements change from experiment to experiment, and the instrument that survives in that environment is the one that covers the widest envelope of voltage, timing, and load conditions without hardware changes. The PVX-4110 anchors the lab’s pulsed voltage capability across that envelope.

## Application Context

Developing a semiconductor metrology technique means iterating. A detection scheme is prototyped, an electrode geometry changes, a gating requirement tightens, and the pulsed voltage requirement moves with each revision. Procurement for this kind of program selects against single-purpose pulse electronics, because a driver matched to one experiment becomes shelf stock at the next design review. The working requirement is an instrument-grade pulse generator with enough voltage headroom and configuration range to follow the research wherever it goes.

## Instrument Configuration

The PVX-4110 provides pulsed output to 10 kV, configured per experiment through its pulse width, repetition rate, and amplitude settings. In R&D service the unit moves between test stands rather than living in one fixture, which makes the built-in safety interlock and overcurrent shutdown part of the daily workflow rather than a commissioning checkbox. Specific waveform parameters in current use are internal to the customer’s development program. \[verify with engineering: insert datasheet rise time, pulse width range, and repetition rate before publish\]

![](https://www.berkeleynucleonics.com/wp-content/uploads/Pulsed-High-Voltage-PVX-4110-1024x826.png)

## Key Specifications



| Parameter | PVX-4110 |
| --- | --- |
| Output voltage | Up to 10 kV |
| Rise / fall time | <60ns |
| Pulse width range | <200ns to DC |
| Maximum repetition rate | 10 kHz |
| Protection | Safety interlock, overcurrent shutdown \[verify wording against datasheet\] |

## Why BNC for This Application

R&D instrumentation is a bet on range. The PVX-4110’s 10 kV ceiling gives a metrology development lab voltage headroom above most electrode and gating requirements it will encounter, and the PVX architecture is designed for repetitive switching into the reactive loads that real instrument hardware presents. One pulse generator covers the experiment running today and the one proposed next quarter. That is the specification that matters in a lab whose requirements are defined by what has not been built yet.

## Scope a Pulsed Voltage Platform

Review the PVX-4110 datasheet, or contact BNC applications engineering to scope a pulsed voltage platform for your development program.